The stilt plus four (S+4) policy in Haryana lets owners of eligible residential plots in HSVP sectors and DTCP-licensed colonies build a stilt parking floor plus four habitable floors, often using purchasable FAR, so each floor can work as an independent dwelling unit. The policy has had an uneven history. After it was introduced, approvals were paused in 2023 amid resident concerns over parking, infrastructure and structural safety, and later permitted again in a more conditional form. Eligibility now depends on where your plot is, the road width, parking and other conditions, so check the current status for your sector before you design or buy.

This guide explains what S+4 allows, which conditions typically apply, how to check your plot's status, and what buyers of S+4 floors should verify.

What the S+4 Policy Allows

Traditionally, many Haryana plotted sectors were planned for a ground floor plus two or three floors. The S+4 framework allows, on eligible plots:

  • Stilt floor for parking, typically not counted in FAR when kept open for parking and permitted services.
  • Four floors above the stilt, each usable as a separate dwelling unit.
  • Additional FAR through purchasable or enhanced FAR, on payment of charges set by the state, so that four full floors fit within the allowed area.
  • Separate dwelling units on each floor, enabling the builder floor model that is now common in Gurugram and Faridabad sectors.

The height, coverage and setbacks for an S+4 building still come from the plot's zoning plan and the Haryana Building Code, as amended.

Free · No sign-upTry it in 3DPlot, Setback & FAR VisualizerSee your plot’s setbacks, buildable envelope and the floors you can build under FAR, in 3D.Open tool

A Short History of the Policy

PhaseWhat happened (in brief)Effect on owners
IntroductionHaryana permitted stilt plus four floors on eligible residential plots, with purchasable FARBuilder floor redevelopment grew rapidly in older sectors
Resident concernsResidents' associations raised parking shortages, water and sewer overload, and safety of shared wallsPressure for review
Pause (2023)New S+4 approvals were put on hold while an expert committee reviewed the policyPending projects stalled; owners had to wait or build to the older floor limits
Conditional revival (2024)The state allowed S+4 again subject to conditions, with certain areas or sectors eligibleEligibility now plot- and sector-specific

Policy notifications on S+4 have changed more than once. Always check the latest notification from the Town and Country Planning Department or HSVP before relying on any of the above.

Free toolFAR / FSI & Setback CalculatorHow much can you legally build on your plot — FAR, ground coverage, floors.Try it free

Conditions That Typically Apply

The exact conditions are set in the current notification, but these are the areas they usually cover:

Condition areaWhat is typically checkedWhy
Road widthPlot abuts a road of at least a minimum widthTraffic, parking and fire access
ParkingRequired parking for every dwelling unit within the plot, usually in the stiltAvoid street parking overload
Sector or area eligibilitySector's services capacity and layout plan permit additional unitsWater, sewer and power load
Structural safetyStructural design and stability certificate for the full S+4 building; protection of adjoining structuresShared walls and old neighbouring houses
Adjoining plotsSome versions of the policy have addressed neighbour consent or safeguards for common wallsDispute and damage risk
Fire and heightCompliance with fire provisions if the building crosses the relevant height thresholdLife safety
ChargesPurchasable FAR and related charges paidRevenue for infrastructure augmentation

How to Check Whether Your Plot Qualifies

  1. Confirm the plot type: HSVP sector plot or DTCP-licensed colony plot. Other categories (municipal areas, villages) follow different rules.
  2. Get the zoning plan for your plot and check the permitted storeys, height and setbacks.
  3. Measure the road width in front of the plot from the approved layout, not by eye.
  4. Check the latest S+4 notification and any list of eligible sectors or areas on the official DTCP or HSVP website.
  5. Check your plot account: dues, extension fees and transfer status, especially on HSVP plots.
  6. Test parking: can the stilt actually hold the required cars for four units, plus the staircase, lift and meter room? On many narrow plots it cannot.

Our DTCP Haryana guide explains how licences and zoning plans work.

Design Realities of an S+4 Building

Four floors over a stilt on a 200 to 350 sq yd plot is a tight brief. The design issues we solve on every S+4 project:

  • Lift and stair core: a lift is practically essential for the third and fourth floors. Core placement decides how efficient each floor is.
  • Parking geometry: car bays, columns and the stair core must coexist in the stilt. Column grid is planned around parking first.
  • Height budget: stilt height, four floor heights and the plinth must fit within the permitted height, leaving reasonable ceilings.
  • Foundations and structure: a five-level building on a plot designed for three needs proper soil investigation and structural design, and care with neighbouring foundations during excavation.
  • Services: separate meters, water storage per unit, sewer capacity and overhead tank loads on the roof.
  • Daylight and privacy: lower floors in tightly packed sectors can be dark; light wells help.

See our stilt parking house design guide for stilt layout options, and builder floor construction cost for budgets. Standard-quality construction typically falls within ₹2,050–₹2,850 per sq ft before city adjustment, with Gurugram running higher.

S+4 vs Building Fewer Floors: Which Makes Sense?

Even where S+4 is allowed, it is not always the right choice. Compare the options for a typical sector plot:

FactorStilt + 3 or fewer floorsStilt + 4 floors
Approval complexityLower; standard zoning planHigher; eligibility, FAR purchase and conditions
Extra chargesUsually none beyond standard feesPurchasable FAR and related charges
LiftOptional for G+2, advisable for G+3Practically essential
Parking pressureManageable in most stiltsTight; may decide the whole layout
Structure and foundationsConventionalHeavier loads; soil test and careful design needed
Saleable unitsThree or fewerFour
Best forFamilies building for own useOwners redeveloping for sale or rental income

If you are building mainly for your own family, the extra floor may add cost and complexity without much benefit. If you are redeveloping an old house to sell floors, the fourth unit often improves the numbers, provided the plot truly qualifies and parking works.

Buying an S+4 Floor: What to Verify

If you are buying a floor in a stilt plus four building, ask for:

  • The sanctioned building plan showing S+4, not an older plan for fewer floors.
  • Proof that purchasable FAR and related charges were paid.
  • The occupation certificate for the building, or at least a clear timeline for it.
  • Your floor's registration and title documents, including how independent floors are registered under current Haryana practice.
  • Allotted parking in the stilt, in writing.
  • Structural stability certificate and the name of the structural engineer.
  • Share of terrace, roof and common areas, and who maintains the lift.

Our independent floor vs apartment comparison covers the wider pros and cons.

Disclaimer: S+4 eligibility, conditions and charges are set by state notifications that have changed several times. This guide is general information only; confirm the current position on the official DTCP or HSVP portal.

Plan Your S+4 Project With a Team That Checks Eligibility First

Panache Architect has designed stilt plus floors across Gurugram and Faridabad. We check your plot's eligibility under the current notification, test parking and structure on paper, then prepare sanction drawings and handle the approval. Book a free consultation with your plot papers, or see our building approvals service.