Stilt parking rules in Delhi NCR generally let you build an open, pillared floor at ground level for car parking that is not counted in FAR, provided it stays open on its sides, is used only for parking and a few permitted services, and stays within a height band set by the authority. Delhi, Haryana (HSVP, DTCP, MCG, MCF) and Noida, Greater Noida and Ghaziabad all follow this basic idea, but they differ in the permitted stilt height, what may be enclosed, and whether a stilt allows extra building height. Enclosing a stilt into a room, shop or office is one of the most common violations in NCR homes.
This guide compares the rules across authorities. For layout ideas, see our stilt parking house design guide.
Why Codes Treat Stilts Differently
Authorities want cars off the street. To encourage owners to give up ground-floor living space for parking, most NCR codes offer incentives:
- FAR exemption: the stilt area used for parking is not counted in the permitted floor area.
- Height concession: some codes allow the building's total height to increase by the stilt height, so you do not lose a floor.
- Parking compliance: the stilt counts towards the required number of parking spaces, which matters for builder floors with several units.
In return, the stilt must remain genuinely open and used for parking. If it is enclosed or converted, it loses these concessions and becomes a violation.
Free · No sign-upTry it in 3DPlot, Setback & FAR VisualizerSee your plot’s setbacks, buildable envelope and the floors you can build under FAR, in 3D.Open toolAuthority Comparison Table
The table summarises how each authority typically treats stilts. Exact heights, permitted enclosures and FAR provisions change with amendments, so treat the entries as directions to check, not final figures.
| Authority | FAR treatment of stilt | Stilt height | Extra building height for stilt | Typically allowed inside the stilt |
|---|---|---|---|---|
| Delhi (MCD / DDA areas, UBBL) | Excluded when used for parking | Within a band set by the bye-laws | Bye-laws have allowed additional height where stilt parking is provided | Parking, staircase, lift, guard cabin, meter/ service areas within limits |
| Haryana HSVP sectors | Excluded as per zoning plan / Haryana Building Code | As per code and zoning plan | Depends on plot's zoning plan and S+4 provisions | Parking, stair and lift core, permitted service rooms |
| DTCP-licensed colonies | Excluded under Haryana Building Code | As per code | As per code and current S+4 policy | Parking, stair and lift core, permitted service rooms |
| MCG / MCF municipal areas | Generally as per Haryana Building Code | As per code | Subject to road width | Parking and core |
| Noida Authority | Excluded when used for parking, as per Noida regulations | As per regulations | Check current regulations | Parking, stair, lift, guard room |
| Greater Noida Authority | Similar approach to Noida, with its own regulations | As per regulations | Check current regulations | Parking and core |
| Ghaziabad (GDA) | As per UP building bye-laws | As per bye-laws | Check current bye-laws | Parking and core |
Note: stilt rules vary by authority and are revised. Confirm the current figures on the official portal or in your plot's zoning plan before finalising design.
Free toolFAR / FSI & Setback CalculatorHow much can you legally build on your plot — FAR, ground coverage, floors.Try it freeStilt Height: The Practical Range
Codes generally specify a stilt height band, measured from the finished stilt floor to the underside of the beam or slab. In practice, NCR stilts are usually designed so that clear height under beams is in the region of about 2.4 to 3.0 m, which suits cars and SUVs and leaves room for services. Points to watch:
- Too low: SUVs, roof carriers and ceiling-mounted pipes clash. Ramps into the stilt reduce effective height further.
- Too high: a stilt beyond the permitted height may be treated as a habitable floor and counted in FAR or height.
- Beams and services: the clear height under deep beams, sewer lines and water pipes is what matters to the car.
- Plinth and ramp: raising the stilt above road level for flood protection needs a ramp within the plot, not in the public drain or road.
What Can and Cannot Be Enclosed
| Item in stilt | Typical position | Common mistake |
|---|---|---|
| Staircase and lift | Usually permitted, enclosed as a core | Oversized lobby that becomes a room |
| Guard room / cabin | Often permitted within a small area limit | Guard room expanded into a servant quarter |
| Meter room, electrical panel | Often permitted within limits | Converted into a store or office |
| Toilet for driver or guard | Permitted in some codes, within limits | Full bathroom plus bedroom |
| Rooms, shops, offices | Not permitted | Shutters on the stilt front to create a shop |
| Side walls on all four sides | Usually not permitted; stilt must be open | Brick infill between columns |
| Grill or gate at the front | Often accepted for security if it does not enclose the space | Solid rolling shutter |
Parking Bays and Numbers
A stilt is only useful if it actually fits cars. Typical planning dimensions, used in most layouts:
- Car bay: about 2.5 m × 5.0 m per car (larger for SUVs).
- Driving aisle for perpendicular parking: about 5.5–6 m where cars turn into bays.
- Column spacing planned so that two or three cars fit between columns.
- Stair and lift core placed at the rear or side so it does not block bays.
On a 10 m wide plot, two or three cars side by side is realistic. On a 7.5 m wide plot, two cars in tandem or side by side with tight clearances is typical. The number of spaces required depends on dwelling units and the authority's parking norms. Our car parking design guide covers ramps, turning and gate widths.
Stilt Rules and Builder Floors
For builder floors with three or four units, the stilt carries the parking compliance for every unit. This is why stilt layouts get close scrutiny in Haryana under the stilt plus floors framework and in Delhi for multi-unit plots. Buyers should check:
- That the sanctioned plan shows a stilt with the number of bays claimed.
- That their parking bay is allotted in writing.
- That the stilt has not been partly enclosed for a shop or room, which risks action against the whole building.
Enforcement and What Happens If You Enclose a Stilt
Enclosing a stilt changes it from an exempt parking floor to built-up area. Typical consequences:
- Objection at occupation certificate stage, with the OC withheld until the enclosure is removed.
- FAR breach, because the stilt area is now counted.
- Notices for unauthorised construction, possible sealing of the enclosed part, and in some cases demolition.
- Problems at resale, as buyers' lawyers and banks compare the building with the sanctioned plan.
Some authorities offer compounding for limited deviations, but conversion of a stilt to a habitable room or shop is usually not something you can regularise easily. Our FAR and bye-laws guide explains how such areas get counted.
Stilt Checklist to Share With Your Architect
- Which authority's stilt height band applies, and is it measured to the slab or the beam?
- Does the stilt give extra building height on this plot, or does it eat into the height cap?
- How many parking spaces does the sanction need for the number of units planned?
- Where will the stair, lift, meter room and guard cabin go without blocking bays?
- What plinth level is needed for flooding, and where will the ramp fit within the plot?
- Which services (sewer, water, electrical) run under the stilt slab, and at what height?
Design a Compliant Stilt From Day One
Panache Architect designs stilt floors that fit real cars, meet the stilt rules of your authority and keep the height for the floors above. We prepare and submit sanction drawings and handle the occupation certificate. See our building approvals service or book a free consultation to check your plot.